应用循环伏安法,研究了对乙酰氨基酚(PCT)在活化玻碳电极上的电化学行为.在pH=4.00的HAc-NaAc缓冲溶液中,PCT的CV扫描于0.54 V左右出现一对明显的氧化-还原峰.电极反应为2电子、2质子的受吸附控制的准可逆过程.其氧化峰电流与PCT浓度在8.00×10-6~2.00×10-4mol.L-1范围内呈良好的线性关系,相关系数r=-0.99918;检出限为6.34×10-6mol.L-1.用于药物样品PCT的含量测定,结果满意. The electrochemical behavior of paracetamol(PCT) was studied at glassy carbon electrode activated by cyclic voltammetry.In HAc-NaAc buffer solution(pH=4.00),a couple of sensitive redox peaks were recorded about 0.54 V in the cyclic voltammograms.The result indicated that the process was controlled by adsorption and nearly reversible.The reaction electron and proton numbers were estimated,respectively,to be two.Excllent linearity was observed in the correlation between the oxidation peak current and the concentration of PCT in the range of 8.00×10-6~2.00×10-4 mol·L-1.The correlative coefficient was-0.999 18.The detection limit was 6.34×10-6 mol·L-1.This method can be used for the determination of PCT real samples.