Show simple item record

dc.contributor.authorSun, Qianzh_CN
dc.contributor.authorChen, Zuliang( Univ S Australia, Ctr Environm Risk Assessment & Remediat, Mawson Lakes, SA 5095, Australia)zh_CN
dc.contributor.authorYuan, Dongxingzh_CN
dc.contributor.author袁东星zh_CN
dc.contributor.authorMegharaj, Mallavarapu( Univ S Australia, Ctr Environm Risk Assessment & Remediat, Mawson Lakes, SA 5095, Australia)zh_CN
dc.contributor.authorNaidu, Ravendra( Univ S Australia, Ctr Environm Risk Assessment & Remediat, Mawson Lakes, SA 5095, Australia)zh_CN
dc.date.accessioned2011-04-26T08:02:20Z
dc.date.available2011-04-26T08:02:20Z
dc.date.issued2009-12zh_CN
dc.identifier.citationRAPID COMMUNICATIONS IN MASS SPECTROMETRY,2009,23(23):3795-3802zh_CN
dc.identifier.issn0951-4198zh_CN
dc.identifier.urihttp://dx.doi.org/doi:10.1002/rcm.4321zh_CN
dc.identifier.urihttps://dspace.xmu.edu.cn/handle/2288/1793
dc.description.abstractOn-line solid-phase extraction (SPE) for pre-concentration and sample cleanup is one strategy to reduce matrix effects and to simultaneously improve detection sensitivity in liquid chromatography/ mass spectrometry (LC/MS). This paper describes an on-line SPE-LC/MS method for the determination of tributyltin (TBT) and triphenyltin (TPhT) at trace levels in water samples. The direct coupling of an on-line C-18 pre-column to LC/MS was used to pre-concentrate TBT and TPhT at trace levels from waters and to remove interfering matrix effects. Pre-concentration was followed by separation of TBT and TPhT on a C-18 column using a mobile phase containing 0.1% (v/v) HCOOH/ 5 mM HCOONH4 and methanol. While both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) can be interfaced with MS for the detection of TBT and TPhT, ESI-MS was preferred for this application. The calibration curve for the targets was linear in the concentration range 0.1-30 mu g L-1. The detection limit (signal-to-noise (S/N) ratio = 3) was 0.02 mu g L-1 when 3.0 mL of sample was enriched on the C18 pre-column. The recoveries of TBT and TPhT in spiked waters were from 81.0 to 101.9%. The reproducibilities for the analysis of the standard mixture (10 mu g L-1) for TBT and TPhT were 13.1 and 5.0%, respectively. The developed method was an easy and fast way to analyze TBT and TPhT in water samples. Copyright (c) 2009 John Wiley & Sons, Ltd.zh_CN
dc.description.sponsorshipState Scholarship Fund of Chinazh_CN
dc.language.isoenzh_CN
dc.publisherJOHN WILEY & SONS LTDzh_CN
dc.titleOn-line solid-phase extraction coupled with liquid chromatography/electrospray ionization mass spectrometry for the determination of trace tributyltin and triphenyltin in water sampleszh_CN
dc.typeArticlezh_CN


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record