Show simple item record

dc.contributor.author游文玮
dc.contributor.author刘彦
dc.contributor.author王尊本
dc.date.accessioned2016-05-17T02:56:36Z
dc.date.available2016-05-17T02:56:36Z
dc.date.issued1999
dc.identifier.citation福州大学学报(自然科学版),1999,(S1):242-244
dc.identifier.issn1000-2243
dc.identifier.otherFZDZ1999S1115
dc.identifier.urihttps://dspace.xmu.edu.cn/handle/2288/107783
dc.description.abstract还原型谷胱甘肽(gSH) 在新亚铜试剂存在下能被Cu2 + 氧化而产生Cu+ 络合物, 该络合物在454nM 处有特征吸收. 采用导数动力学分光光度法间接测定gSH. 系统研究了导数动力学方法的实验条件, 并对流动注射装置进行改进, 保证导数光谱峰高的准确测量. 实验结果表明, 加入导数技术可基本消除因采样时间不准给流动注射方法带来的误差.
dc.description.abstractReduced glutathione(GSH) ,mixed with copper( Ⅱ)and buthocuproine,could beox idized to copper( Ⅰ)complex , which had a characteristic absorption at 454nm .GSH wasindi rectly determined by derivative kineticspectrophotometry .The experimentalconditions weresys tematically studied andtheapparatusofflow injection wasimproved to ensurethe accurate detec tion .The resultsshowed that derivative method could effectively eliminatethe deviation ofsam pling time by flow injection .
dc.language.isozh_CN
dc.subject导数光度法
dc.subject催化动力学
dc.subject分光光度法
dc.subject停流法
dc.subject还原型谷胱甘肽
dc.subjectderivative spectrometry
dc.subjectcatalytic kinetic
dc.subjectspectrophotometry
dc.subjectstopflow technique
dc.subjectreduced glutathione
dc.title一阶导数停流法测定还原型谷胱甘肽的方法研究
dc.title.alternativeStudy on the First Derivative Stop - Flow Method to Determine Reduced Glutathione
dc.typeArticle