利用导电涂膜直接电解海水法防护生物腐蚀1.模拟和测量技术
Direct Electrolysis of Seawater on Conducting Film for Microbial Anticorrosion 1. Simulation and Measurement Technique
Abstract
基于电化 学微探针 和微弱 信号检测 技术, 采用 四电 极体 系、双恒 电 位仪、锁相 相 关测定系统 以及三维 微调装 置建立模 拟和测量 系统,将 首次实 现对利 用导 电涂 膜直 接电 解海 水法 防护生物腐 蚀中微 米尺度内 痕量 Cl O - 浓度 的测量.本 文报道 了模拟和 测量实验 的阶段 性进展. Based on the electrochemical micro probe and the weak signal detection technique, simulated test and measurement system were set up by the use of four_electrode cell(including a micro electrode), bipotentiostat, lock_in amplifier and three_dimensional micro manipulating device.Based on the system, the micrometer scale concentration distribution of trace hypochlorite, which is produced by direct electrolysis of seawater on the conducting film for preventing microbial corrosion has been obtained for the first time.Both relationships between concentration of hypochlorite and its reduction current, which is termed an working curve, and between the reduction current of hypochlorite and measured time are reported.